WTI CPM-1600-1-CA
The WTI CPM-1600-1-CA is a 2U infrastructure device from WTI. It features 1 network interfaces. The NDX catalog provides enrichment data across 5 categories including thermal, environmental, operational, platform.
Last verified: June 2, 2026
Key Facts
| Manufacturer | WTI |
|---|---|
| Model | CPM-1600-1-CA |
| Part Number | CPM-1600-1-CA |
| Type | Device Type |
| Form Factor | 2U, half-depth |
| Airflow | passive |
| Weight | 10 kg |
| Interfaces | 1 ports |
| Source | NetBox Labs |
| Enrichment | 5 categories available |
Specifications
Interfaces (1)
| Name | Type | Mgmt Only | Label |
|---|---|---|---|
| ETH0 | 1000base-t |
Power Ports (4)
| Name | Type | Max Draw (W) | Allocated (W) |
|---|---|---|---|
| A1-A4 | iec-60320-c20 | 14 | 7 |
| A5-A8 | iec-60320-c20 | 14 | 7 |
| B1-B4 | iec-60320-c20 | 14 | 7 |
| B5-B8 | iec-60320-c20 | 14 | 7 |
Console Ports (1)
| Name | Type |
|---|---|
| Console | usb-mini-b |
Console Server Ports (16)
| Name | Type |
|---|---|
| port1 | rj-45 |
| port2 | rj-45 |
| port3 | rj-45 |
| port4 | rj-45 |
| port5 | rj-45 |
| port6 | rj-45 |
| port7 | rj-45 |
| port8 | rj-45 |
| port9 | rj-45 |
| port10 | rj-45 |
| port11 | rj-45 |
| port12 | rj-45 |
| port13 | rj-45 |
| port14 | rj-45 |
| port15 | rj-45 |
| port16 | rj-45 |
Power Outlets (16)
| Name | Type | Feed Leg |
|---|---|---|
| Outlet_A1 | nema-5-15r | |
| Outlet_A2 | nema-5-15r | |
| Outlet_A3 | nema-5-15r | |
| Outlet_A4 | nema-5-15r | |
| Outlet_A5 | nema-5-15r | |
| Outlet_A6 | nema-5-15r | |
| Outlet_A7 | nema-5-15r | |
| Outlet_A8 | nema-5-15r | |
| Outlet_B1 | nema-5-15r | |
| Outlet_B2 | nema-5-15r | |
| Outlet_B3 | nema-5-15r | |
| Outlet_B4 | nema-5-15r | |
| Outlet_B5 | nema-5-15r | |
| Outlet_B6 | nema-5-15r | |
| Outlet_B7 | nema-5-15r | |
| Outlet_B8 | nema-5-15r |
Data Sources & Provenance
| Field | Type | Confidence | Source |
|---|---|---|---|
| thermal.cooling_type | vendor product page | medium-high | www.wti.com |
| environmental.max_operating_temp_c | vendor product page | medium-high | www.wti.com |
| operational.max_power_draw_watts | vendor product page | medium-high | www.wti.com |
| operational.typical_power_draw_watts | vendor product page | medium-high | www.wti.com |
| environmental.min_operating_temp_c | vendor product page | high | www.wti.com |
| environmental.operating_humidity_min | vendor product page | high | www.wti.com |
| environmental.operating_humidity_max | vendor product page | high | www.wti.com |
| environmental.operating_altitude_m | vendor product page | high | www.wti.com |
| operational.noise_level_dba | vendor product page | high | www.wti.com |
| dtl.interfaces | vendor product page | high | www.wti.com |
| dtl.console-ports | vendor product page | high | www.wti.com |
| dtl.power-ports | vendor product page | high | www.wti.com |
| dtl.u_height | vendor product page | high | www.wti.com |
| dtl.is_full_depth | vendor product page | high | www.wti.com |
| dtl.airflow | vendor product page | high | www.wti.com |
| dtl.part_number | vendor product page | high | www.wti.com |
| dtl.weight | vendor product page | medium-high | www.wti.com |
| snmp.versions | vendor product page | high | www.wti.com |
| snmp.vendor_oid_prefix | third party | high | www.iana.org |
| snmp.sys_object_id | vendor documentation | medium-high | www.wti.com |
Showing 20 of 22 provenance entries.
Frequently Asked Questions
What is the WTI CPM-1600-1-CA?
The WTI CPM-1600-1-CA is a 2U infrastructure device from WTI. It features 1 network interfaces. The NDX catalog provides enrichment data across 5 categories including thermal, environmental, operational, platform.
What is the form factor of the WTI CPM-1600-1-CA?
The WTI CPM-1600-1-CA is a 2U half-depth device with passive airflow. It weighs 10 kg.
How many ports does the WTI CPM-1600-1-CA have?
The WTI CPM-1600-1-CA has 1 network interfaces: 1x 1000base-t.
What are the power requirements for the WTI CPM-1600-1-CA?
The WTI CPM-1600-1-CA has 4 power ports (iec-60320-c20, iec-60320-c20, iec-60320-c20, iec-60320-c20). Maximum power draw is 56W.
What operational data is available for the WTI CPM-1600-1-CA?
The NDX catalog includes enrichment data for the WTI CPM-1600-1-CA in the following categories: thermal, environmental, operational, platform, snmp. Full enrichment values are available through NetBox Cloud or Enterprise.
How do I add the WTI CPM-1600-1-CA to NetBox?
You can import the WTI CPM-1600-1-CA directly into NetBox via the NDX features available in NetBox Cloud and NetBox Enterprise. NetBox Community users may download the YAML type definition and import it manually.
Where does the WTI CPM-1600-1-CA data come from?
The WTI CPM-1600-1-CA device type definition was created and is maintained by NetBox Labs as part of the NDX catalog.
Related Devices from WTI
Last verified June 2, 2026.
Enrichment Availability
| Category | Available |
|---|---|
| Lifecycle | |
| Thermal | |
| Environmental | |
| Operational | |
| Platform | |
| SNMP | |
| gNMI | |
| NETCONF | |
| Redfish | |
| Modbus | |
| Imagery |
Access full enrichment data with NetBox Cloud or Enterprise.