Schweitzer Engineering Laboratories SEL-2407
The Schweitzer Engineering Laboratories SEL-2407 is a 1U infrastructure device from Schweitzer Engineering Laboratories. It features 9 network interfaces. The NDX catalog provides enrichment data across 5 categories including lifecycle, thermal, environmental, operational.
Last verified: May 3, 2026
Key Facts
| Manufacturer | Schweitzer Engineering Laboratories |
|---|---|
| Model | SEL-2407 |
| Part Number | SEL-2407 |
| Type | Device Type |
| Form Factor | 1U, half-depth |
| Weight | 3.2 kg |
| Interfaces | 9 ports |
| Source | NetBox Labs |
| Enrichment | 5 categories available |
Specifications
Interfaces (9)
| Name | Type | Mgmt Only | Label |
|---|---|---|---|
| Ethernet 1 | 100base-tx | NTP | |
| Ethernet 2 | 100base-tx | NTP | |
| Ethernet 3 | 100base-tx | NTP | |
| Ethernet 4 | 100base-tx | NTP | |
| IRIG-B Output 1 | other | IRIG-B/PPS output (BNC) | |
| IRIG-B Output 2 | other | IRIG-B/PPS output (BNC) | |
| IRIG-B Output 3 | other | IRIG-B/PPS output (BNC) | |
| IRIG-B Output 4 | other | IRIG-B/PPS output (BNC) | |
| GPS Antenna | other | TNC GPS antenna connector |
Power Ports (2)
| Name | Type | Max Draw (W) | Allocated (W) |
|---|---|---|---|
| Power Supply A | dc-terminal | 25 | |
| Power Supply B | dc-terminal | 25 |
Console Ports (1)
| Name | Type |
|---|---|
| Console | de-9 |
Data Sources & Provenance
| Field | Type | Confidence | Source |
|---|---|---|---|
| thermal.tdp_watts | vendor product page | medium-high | selinc.com |
| environmental.max_operating_temp_c | vendor product page | medium-high | selinc.com |
| thermal.cooling_type | vendor product page | medium-high | selinc.com |
| lifecycle.ga_date | vendor product page | medium-high | selinc.com |
| operational.max_power_draw_watts | vendor product page | medium-high | selinc.com |
| operational.typical_power_draw_watts | vendor product page | medium-high | selinc.com |
| environmental.min_operating_temp_c | vendor product page | medium-high | selinc.com |
| environmental.operating_humidity_min | vendor product page | medium-high | selinc.com |
| environmental.operating_humidity_max | vendor product page | medium-high | selinc.com |
| environmental.operating_altitude_m | vendor product page | medium-high | selinc.com |
| dtl.interfaces | vendor product page | high | selinc.com |
| dtl.console-ports | vendor product page | high | selinc.com |
| dtl.power-ports | vendor product page | high | selinc.com |
| dtl.u_height | vendor product page | high | selinc.com |
| dtl.is_full_depth | vendor product page | high | selinc.com |
| dtl.weight | vendor product page | high | selinc.com |
| dtl.part_number | vendor product page | high | selinc.com |
| platform.nos | vendor product page | medium-high | selinc.com |
| platform.api_types | heuristic | medium | derived from extension blocks and cli_protocol |
Frequently Asked Questions
What is the Schweitzer Engineering Laboratories SEL-2407?
The Schweitzer Engineering Laboratories SEL-2407 is a 1U infrastructure device from Schweitzer Engineering Laboratories. It features 9 network interfaces. The NDX catalog provides enrichment data across 5 categories including lifecycle, thermal, environmental, operational.
What is the form factor of the Schweitzer Engineering Laboratories SEL-2407?
The Schweitzer Engineering Laboratories SEL-2407 is a 1U half-depth device. It weighs 3.2 kg.
How many ports does the Schweitzer Engineering Laboratories SEL-2407 have?
The Schweitzer Engineering Laboratories SEL-2407 has 9 network interfaces: 5x other, 4x 100base-tx.
What are the power requirements for the Schweitzer Engineering Laboratories SEL-2407?
The Schweitzer Engineering Laboratories SEL-2407 has 2 power ports (dc-terminal, dc-terminal). Maximum power draw is 50W.
Is the Schweitzer Engineering Laboratories SEL-2407 still supported?
Lifecycle data is available for the Schweitzer Engineering Laboratories SEL-2407 in the NDX catalog. Access full lifecycle dates including general availability, end-of-sale, and end-of-support through NetBox Cloud or Enterprise.
What operational data is available for the Schweitzer Engineering Laboratories SEL-2407?
The NDX catalog includes enrichment data for the Schweitzer Engineering Laboratories SEL-2407 in the following categories: lifecycle, thermal, environmental, operational, platform. Full enrichment values are available through NetBox Cloud or Enterprise.
How do I add the Schweitzer Engineering Laboratories SEL-2407 to NetBox?
You can import the Schweitzer Engineering Laboratories SEL-2407 directly into NetBox via the NDX features available in NetBox Cloud and NetBox Enterprise. NetBox Community users may download the YAML type definition and import it manually.
Where does the Schweitzer Engineering Laboratories SEL-2407 data come from?
The Schweitzer Engineering Laboratories SEL-2407 device type definition was created and is maintained by NetBox Labs as part of the NDX catalog.
Related Devices from Schweitzer Engineering Laboratories
Last verified May 3, 2026.
Enrichment Availability
| Category | Available |
|---|---|
| Lifecycle | |
| Thermal | |
| Environmental | |
| Operational | |
| Platform | |
| SNMP | |
| gNMI | |
| NETCONF | |
| Redfish | |
| Modbus | |
| Imagery |